Code: SC320
Description: Polygon mirror motor error -Definition- [B] The polygon mirror motor does not reach its operating speed within 10 seconds after the polygon mirror motor on signal, or the lock signal is not detected for more than 10 seconds continuously during operation.
Causes: · Polygon mirror motor defective · Poor connection between the polygon mirror motor driver and the BECU board · BECU board defective