Code: 353-00
Description: ID sensor: Auto adjustment PWM value error (detailed)
Causes: One of the following conditions occurs when the ID sensor is adjusting Vsg automatically, this SC is issued (only when the SP5-995-001 is set to “1”). • Vsg is less than 4 V with the LED drive current set to maximum (PWM=1023). • Vsg is more than 4 V with the LED drive current set to minimum (PWM=1). • ID sensor defective • ID sensor harness damaged. • ID sensor not connected correctly. • MPU defective • Laser unit defective • Imaging density fault • HVPS board defective • ID sensor dirt
Remedy: • Clean the ID sensor. • Replace the ID sensor. • Replace and reset the ID sensor harness. • Replace the MPU. • Replace the HVPS board.