Mã lỗi A100 — Brother DCP8112DN

Code: A100

Description: The front cover sensor detected that the front cover was open.
Causes: 1 Connection failure of the front cover sensor harness. 2 Connection failure of the relay front harness. 3 Front cover sensor attachment failure. 4 Broken rib (inside the front cover) where the front cover sensor is pressed. 5 Front cover sensor failure. 6 Relay front PCB failure. 7 Main PCB failure.
Remedy: 1 Connection failure of the front cover sensor harness Check the connection of the front cover sensor harness, and reconnect it if necessary. 2 Connection failure of the relay front harness Check the connection of the relay front harness, and reconnect it if necessary. 3 Front cover sensor attachment failure Reattach the front cover sensor. 4 Broken rib (inside the front cover) where the front cover sensor is pressed Replace the front cover. 5 Front cover sensor failure Refer to "1.3.10 Check sensor operation (function code: 32)" in Chapter 5 to check the sensor operation. If the sensor operation is faulty, replace the relay front PCB ASSY. 6 Relay front PCB failure Replace the relay front PCB ASSY. 7 Main PCB failure Replace the main PCB ASSY.

← Xem tất cả mã lỗi Brother DCP8112DN