Code: 722-24
Description: 1000-Sheet Finisher Error: Finisher exit guide plate motor error
The exit guide plate HP sensor did not activate within the prescribed time after the exit guide plate motor turned on.
The exit guide plate HP sensor did not activate within the prescribed time after the exit guide plate motor turned on.
Causes: Finisher exit guide plate motor drive is obstructed (jammed paper, paper
scraps, etc.)
Exit guide plate motor harness loose, broken
Exit guide plate HP sensor harness loose, broken
Exit guide plate motor defective
Exit guide plate HP sensor defective
scraps, etc.)
Exit guide plate motor harness loose, broken
Exit guide plate HP sensor harness loose, broken
Exit guide plate motor defective
Exit guide plate HP sensor defective