Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 36 — Brother DCP9010CN

Code: 36

Description: HVPS PCB error in ready state
Causes: 1 Dirt on drum unit electrodes. 2 Harness connection failure of high-voltage power supply PCB ASSY. 3 HVPS control PCB failure. 4 High-voltage power supply PCB failure. 5 Engine PCB failure. 6 Main PCB failure.
Remedy: 1 Dirt on drum unit electrodes Clean the electrodes of the drum unit and main body. (Refer to Fig. 3-3 (P3-32) and Fig. 3-6 (P3-33).) 2 Harness connection failure of high-voltage power supply PCB ASSY Check the harness connection between the high-voltage power supply PCB ASSY and engine PCB ASSY, and the one between the high-voltage power supply PCB ASSY and main PCB ASSY. Then, reconnect them. 3 HVPS control PCB failure Replace the HVPS control PCB ASSY. 4 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 5 Engine PCB failure Replace the engine PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.

← Xem tất cả mã lỗi Brother DCP9010CN