Code: 42
Description: HVPS control PCB transfer error
Causes: 1 Harness connection failure of high-voltage power supply PCB ASSY. 2 Harness connection failure of HVPS control PCB ASSY. 3 HVPS control PCB failure. 4 High-voltage power supply PCB failure. 5 Main PCB failure.
Remedy: 1 Harness connection failure of high-voltage power supply PCB ASSY Check the harness connection between the high-voltage power supply PCB ASSY and HVPS control PCB ASSY, and reconnect it. 2 Harness connection failure of HVPS control PCB ASSY Check the harness connection between the HVPS control PCB ASSY and main PCB ASSY, and reconnect it. 3 HVPS control PCB failure Replace the HVPS control PCB ASSY. 4 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.