Code: 97
Description: Not supported paper
Causes: 1 Harness connection failure of manual sensor PCB ASSY. 2 Manual sensor failure. 3 Registration front/rear sensor PCB failure. 4 HVPS control PCB failure. 5 Main PCB failure
Remedy: 1 Harness connection failure of manual sensor PCB ASSY Check the harness connection of the manual sensor PCB ASSY and reconnect it. 2 Manual sensor failure Check the sensor performance following the procedure described in “Function code 32”. If any problem occurs, replace the manual sensor PCB ASSY. 3 Registration front/rear sensor PCB failure Replace the registration front/rear sensor PCB ASSY. 4 HVPS control PCB failure Replace the HVPS control PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.