Code: A4
Description: ADF cover opened
Causes: 1 ADF cover open sensor actuator catching on some position. 2 Harness connection failure of ADF sensor PCB. 3 ADF cover is changed in shape or cracked. 4 ADF sensor PCB failure. 5 Main PCB failure.
Remedy: 1 ADF cover open sensor actuator catching on some position. Correct catching of the ADF cover open sensor actuator. 2 Harness connection failure of ADF sensor PCB Check the harness connection of the ADF sensor PCB and reconnect it. 3 ADF cover is changed in shape or cracked. Replace the ADF cover ASSY. 4 ADF sensor PCB failure Replace the ADF sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.