Code: 220
Description: Laser synchronization detection error
The 1st laser synchronization detection unit could not detect the line synchronization signal (DETP0) within 500 ms while the polygon mirror motor was operating at normal speed. Note: The unit polls for the signal every 50 ms. This SC is issued after the 10th attempt fails to detect the signal.
The 1st laser synchronization detection unit could not detect the line synchronization signal (DETP0) within 500 ms while the polygon mirror motor was operating at normal speed. Note: The unit polls for the signal every 50 ms. This SC is issued after the 10th attempt fails to detect the signal.
Causes: • Laser synchronization board connector loose, broken, defective
• Laser synchronization detection board is not installed correctly (out of alignment)
• Laser synchronization board defective • IPU defective
• Laser synchronization detection board is not installed correctly (out of alignment)
• Laser synchronization board defective • IPU defective