Code: 316
Description: Potential sensor calibration error 6
During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range.
During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range.
Causes: • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective