Code: 735
Description: Finisher pre-stack motor error
• The pre-stack motor starts but does not return to the home position within 400 pulses. After 2 counts, the SC is logged as a jam.
• Motor does not return to the home position within 280 pulses immediately before or after prestacking. After 2 counts, the SC is logged as a jam.
• The pre-stack motor starts but does not return to the home position within 400 pulses. After 2 counts, the SC is logged as a jam.
• Motor does not return to the home position within 280 pulses immediately before or after prestacking. After 2 counts, the SC is logged as a jam.
Causes: • Jogger HP sensor defective
• Sensor harnesses disconnected, defective
• Pre-stack motor defective
• Finisher main board defective
• Pre-stack motor overload
• Sensor harnesses disconnected, defective
• Pre-stack motor defective
• Finisher main board defective
• Pre-stack motor overload