Code: 312
Description: Potential sensor calibration error 3
During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage). -or- When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (– 800±10 + VL + 130V)
During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage). -or- When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (– 800±10 + VL + 130V)
Causes: • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
• Charge corona unit worn out, dirty
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
• Charge corona unit worn out, dirty