Code: 317
Description: Potential sensor calibration error 7
During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V. (VL is the potential after exposing a white pattern.)
During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V. (VL is the potential after exposing a white pattern.)
Causes: • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Charge corona power pack defective
• Development power pack defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Charge corona power pack defective
• Development power pack defective