Mã lỗi 672 — Ricoh Aficio MP7001

Code: 672

Description: Controller Startup Error
The line between the controller board and the operation panel does not open correctly when the machine is powered on, or after the machine was powered on communication between the controller and operation panel is suspended. The controller board and operation panel could not exchange the handshake (FDH) and acknowledge (FEH) signals within 15 s of the operation panel reset after power on, or after 2 retries there was no response to the transmission line confirmation command issued every 30 s from the operation panel to the controller board.
Causes: • Controller board defective • Controller board installed incorrectly • Operation panel harness connection loose or incorrect
Remedy:

← Xem tất cả mã lỗi Ricoh Aficio MP7001