Code: 82
Description: Density patch measurement is not completed normally when implementing calibration from the control panel.
Causes: 1 Density sensor shutter not operating smoothly or catching in some position. 2 Harness connection failure of density sensor holder ASSY. 3 Density sensor failure. 4 Transfer HVPS PCB failure. 5 Engine PCB failure.
Remedy: 1 Density sensor shutter not operating smoothly or catching in some position Correct smooth operation of the density sensor shutter. 2 Harness connection failure of density sensor holder ASSY Check the harness connection of the density sensor holder ASSY and reconnect it. 3 Density sensor failure Replace the density sensor holder ASSY. 4 Transfer HVPS PCB failure Replace the transfer HVPS PCB ASSY. 5 Engine PCB failure Replace the engine PCB ASSY.