Mã lỗi C4 — Brother DCP9042CDN

Code: C4

Description: Tray 2 (LT) plate-up function malfunction
Causes: 1 Connection failure between the machine and LT connector. 2 Harness connection failure of plate motor ASSY LT. 3 Harness connection failure of LT paper feed frame unit. 4 LT paper feed frame unit failure. 5 Engine PCB failure.
Remedy: 1 Connection failure between the machine and LT connector Replace the connector. 2 Harness connection failure of plate motor ASSY LT Check the harness connection of the plate motor ASSY LT and reconnect it. 3 Harness connection failure of LT paper feed frame unit Check the harness connection of the LT paper feed frame unit and reconnect it. 4 LT paper feed frame unit failure Check the sensor performance following the procedure described in “Maintenance mode 32”. If any problem occurs, replace the LT paper feed frame unit. 5 Engine PCB failure Replace the engine PCB ASSY.