Code: 650
Description: Communication error of the remote service modem (Cumin-M)
Causes: -001 Authentication error The authentication for the Cumin-M fails at a dial up connection.•Incorrect SP settings • Disconnected telephone line • Disconnected modem board 1. Check and set the correct user name (SP5816-156) and password (SP5816-157). -004 Incorrect modem setting Dial up fails due to the incorrect modem setting. Same as -001 1. Check and set the correct AT command (SP5819-160). -005 Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection. Same as -001-011 1. Consult with the user's local telephone company.Incorrect network setting Both the NIC and Cumin-M are activated at the same time. 1. Disable the NIC with SP5985-1. -012 Modem board error The modem board does not work properly even though the setting of the modem board is installed with a dial up connection. Same as -001 1. Install the modem board. 2. Check and reset the modem board setting with SP5816. 3. Replace the modem board.
Remedy: