Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC370-01 — Ricoh Aficio MPC2003

Code: SC370-01

Description: TM (ID) sensor calibration error (F) Regular reflection optical output voltage of the Front or Center or Rear TM (ID) sensor: Vsg_reg cannot be adjusted to within target range. Upper limit (SP3-320-013: initial value 4.5V) Lower limit (SP3-320-014: initial value 3.5V)
Causes: • TM (ID) sensor connector missing/ connection fault • TM (ID) sensor detection window dirt • TM (ID) sensor malfunction • Undulation in the ITB, or belt slippage
Remedy: • Remove image transfer unit, and check for TM (ID) sensor connector missing. If it is missing, reconnect it. • Check for dirt on the ID sensor detection window. If te detection window is dirty, clean by predetermined method (do not wipe dry). • Check the condition of the ITB. If undulation or belt slippage has occurred, re-install or replace the ITB. • If neither of the above have occurred, perform TM (ID) sensor replacement

← Xem tất cả mã lỗi Ricoh Aficio MPC2003

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie