Mã lỗi SC554-02 — Ricoh Aficio MPC2003
Code:
SC554-02
Description: Fusing end NC sensor high temperature detection (hardware) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating edge thermopile defective • Fusing control software: out of control
Remedy: • Attach the new fusing unit, then run SP-5-810-002 • If necessary, replace the BCU or Fusing edge NC sensor