Code: SC700-01
Description: Base Plate Lift Motor Error (1-pass ADF) Even if the base plate motor is rotated in the base plate ascent direction, the base plate paper feed correct position sensor does not detect. Even if the base plate motor is rotated in the base plate descent direction, the base plate home position sensor does not detect.
Causes: • Base plate paper feed correct position sensor error (output error) • Base plate home position sensor error (output error) • Base plate motor error (does not rotate) • Controller error
Remedy: -01, 02 • Check the sensor harness and motor harness connection • Replace the sensor harness and motor harness • Replace the sensor • Replace the motor • Replace the controller -04, 05, 06, 07, 09 • Check the harness connection • Replace the harness • Replace the motor 5. Troubleshooting