Code: SC721-25
Description: Punch Drive Motor Error (1K sheet finisher) • During movement to home, the home position could not be detected within a predetermined time (t0 sec) (1st time is jam notification, 2nd time is SC notification). • During movement from home, the home position was detected even after a predetermined time (t1 sec) elapsed (1st time is jam notification, 2nd time is SC notification). • Output from the encoder could not be counted for a predetermined number of times within a predetermined time (t0 sec) (1st time is jam notification, 2nd time is SC notification). • The time to return to home without fail, the time coming from home, and the time for which the encoder output can be counted during normal operation, are taken as t0, t1 and t2.
Causes: • Over current (board defective, harness short-circuit, solenoid defective) (*721-03 only) • Motor defective (*excluding 721-03) • Connector disconnected (*excluding 721-03) • Overload (*excluding 721-03) • Encoder error (*720-10, 11, 17, 25, 44 only) • Home position sensor error (*Excluding 721-03, 10, 11, 17, 70, and 80) • Retreat sensor error (*721-42 only) • Needle jam (*721-44 only) • Home position sensor (folding blade HP) error (*721-52 only) • Home position sensor (folding cam HP) error (*721-52 only) • Paper surface sensor error (*721-70 only)
Remedy: • Replace the controller • Replace the harness • Replace the motor (*excluding SC721-03) • Reset the connector (*excluding SC721-03) • Replace the solenoid (*SC721-03 only) • Replace the home position sensor (*excluding SC721-03, 10, 11, 17, 80)