Code: 400
Description: ID sensor adjustment error
When the Vsg error counter reaches "3", the machine detects "SC400". The Vsg error counter counts "1" when the Vsg detected by ID sensor is more than the value (default: 4.5V) specified with SP3324-005 or less than the value (default: 3.5V) specified with SP3324-006.
When the Vsg error counter reaches "3", the machine detects "SC400". The Vsg error counter counts "1" when the Vsg detected by ID sensor is more than the value (default: 4.5V) specified with SP3324-005 or less than the value (default: 3.5V) specified with SP3324-006.
Causes: • Dirty or defective ID sensor • Defective ID sensor shutter
Remedy: 1. Check the harness of the ID sensor. 2. Clean or replace the ID sensor. • After replacing the ID sensor, input the ID sensor correction coefficient with SP3362-013 and -016. For details, refer to "ID sensor board" in the Replacement and Adjustment section. 3. Check the spring at the PTR unit contact lever. (See “PTR Unit Contact Motor” in the chapter “Replacement and Adjustment”.) 4. Replace the BCU. 5. Replace the ITB unit.