Code: 547
Description: Zero cross error
• The zero cross signal is detected for 0.05 seconds three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
• The zero cross signal is detected for 0.05 seconds three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Causes: • Defective fusing lamp relay • Defective fusing lamp relay circuit • Unstable power supply
Remedy: 1. Check the power supply source. 2. Replace the shorted 24V fuse on the PSU. 3. Replace the PSU