Code: 210
Description: Laser synchronizing detection error: end position [K]
The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.