Code: 370
Description: ID sensor calibration error
The reflection light output voltage of the ID sensor (Vsg_reg) is not adjusted within the target range. Upper limit: SP3320-013 (default: 4.5 V) Lower limit: SP3320-014 (default: 3.5 V)
The reflection light output voltage of the ID sensor (Vsg_reg) is not adjusted within the target range. Upper limit: SP3320-013 (default: 4.5 V) Lower limit: SP3320-014 (default: 3.5 V)
Causes: Disconnected ID sensor connectors. Dirty or defective ID sensor. Defective image transfer belt
Remedy: 1. Check the connection of the connectors of the ID sensor. 2. Clean or replace the ID sensor. Note: After replacing the ID sensor, input the ID sensor correction coefficient with SP3331. For details, refer to "ID sensor board" in the Replacement and Adjustment section. 3. Replace the image transfer belt unit.