Code: C4
Description: Paper tray 2 pressing plate up/ down error.
Causes: 1 Harness connection failure of T2 plate motor ASSY. 2 Harness connection failure of T2 Relay PCB ASSY. 3 T2 plate-up detection sensor failure. 4 T2 Relay PCB ASSY failuresor failure. 5 Engine PCB failure. 6 T2 plate motor ASSY failurer failure
Remedy: 1 Harness connection failure of T2 plate motor ASSY Check the harness connection of the T2 plate motor ASSY and reconnect it. 2 Harness connection failure of T2 Relay PCB ASSY Check the harness connection of the T2 Relay PCB ASSY and reconnect it. 3 T2 plate-up detection sensor failure Check the sensor performance following the procedure described in “Function code 32”. If any problem occurs, replace the T2 paper feed frame unit. 4 T2 Relay PCB ASSY failure Replace the T2 Relay PCB ASSY. 5 Engine PCB failure Replace the engine PCB ASSY. 6 T2 plate motor ASSY failure Replace the paper tray 2.