Description: FGATE ON error: Y The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and BCU. • Defective BCU
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.