Description: RFID: Communication error • Communication error occurs at communication with the RFID receptor. • Retry of RFID communication failed
Causes: • Defective RFID reader and writer • Disconnected ASAP I/F • No memory chip on the toner cartridge • Noise
Remedy: • Remove and then re-insert each toner bottle. • Replace toner bottle. • Confirm that RFID connectors and harnesses are connected correctly. • If the connectors and harnesses are damaged, replace the RFID_CPU board and Harness: ANTENNA: Toner Supply. • Replace the affected RFID_AFE board (KMCY). (See table below.) • Replace BCU.