Description: LED error The peak white level is less than the prescribed value. This SC is detected when: • The scanner power is on or returning from energy saver mode • ARDF/Book scanning • White plate scan finishes • Shading
Causes: • Condensation in the scanner unit • Connector failure • Defective scanner carriage • BiCU failure • Harness failure • Dirty or defective white plate
Remedy: 1. Check if the SC occurs by turning the power off then on. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step. 2. Reconnect the following connectors. SBU-BiCU harness (FFC) connector SBU-LEDB harness (FFC) connector (SBU) 3. Check the white plate (Exposure glass). Replace the scanner upper cover if the plate is dirty or damaged. 4. Replace the scanner carriage 5. Replace the BiCU. 6. Replace the harness (FFC).