Code: 650
Description: Communication error of the remote service modem (Cumin-M)
Causes: -01 - Authentication error The authentication for the Cumin-M fails at a dial up connection. • Incorrect SP settings • Disconnected telephone line • Disconnected modem board • Disconnected wireless LAN card 1. Check and set the correct user name (SP5-816-156) and password (SP5-816-157). -04 - Incorrect modem setting Dial up fails due to the incorrect modem setting. Same as -01 1. Check and set the correct AT command (SP5-816-160). -05 - Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection. Same as -01 1. Consult with the user's local telephone company. -13 - No modem board Modem board is not installed even though the setting at Cumin-M (During the operation) Same as -01 1. Install the modem board if it is not installed. 2. Check correct setting value for modem driver (SP5-816-160, SP5-816-165 to 171, SP5-816-188 and 189). 3. Replace the modem board. -14 - The modem board is installed The modem board is installed even though the setting at Cumin-N. Or wired/ wireless LAN is not working normally. Same as -01 1. Uninstall the modem board if it is installed. 2. Check that the wired/wireless LAN is working properly.
Remedy: