Code: 370
Description: ID sensor adjustment error
When the Vsg error counter reaches "3", the machine detects "SC370". The Vsg error counter counts "1" when the Vsg detected by ID sensor is more than the value (default: 4.5V) specified with SP3-324-005 or less than the value (default: 3.5V) specified with SP3-324-006.
When the Vsg error counter reaches "3", the machine detects "SC370". The Vsg error counter counts "1" when the Vsg detected by ID sensor is more than the value (default: 4.5V) specified with SP3-324-005 or less than the value (default: 3.5V) specified with SP3-324-006.
Causes: • Dirty or defective ID sensor • ID sensor detection surface dirty
Remedy: 1. Check the harness of the ID sensor. 2. Clean or replace the ID sensor. • After replacing the ID sensor, input the ID sensor correction coefficient with SP3362-013 to -018. For details, refer to "ID sensor board" in the Replacement and Adjustment section. 3. Replace the BCU. 4. Replace the ITB unit.