Description: CIS black level error The black level scanned by CIS is abnormal. The black level average of R, G or B is not within range (2 to 62). 0 < Calibrated Black data level < 255 (10bit).
Causes: • Defective CIS
Remedy: 1. Check or replace the harness (CN220 or CN210 on the DF main board) between the CIS and DF. 2. Replace the CIS on the DF.