Code: SC301
Description: AC charge output error: M
An interrupt checks the status of the power pack every 10 ms. This SC is issued if the VBCU detects a short in the AC charge for M, C, Y.
An interrupt checks the status of the power pack every 10 ms. This SC is issued if the VBCU detects a short in the AC charge for M, C, Y.
Causes: • Disconnect the high voltage cable from Terminal C of the multiple high-voltage supply board. • Attach a voltmeter to the terminal. • If there is no output from the terminal, replace the high voltage power supply. -or- • If there is output from the terminal, test the resistance between the high voltage cable and the ground. If resistance is nearly "0", check the high-voltage harness for defects and replace it if necessary. • Test the conductivity between the OPC unit and the ground. If there is no conductivity between the OPC unit and ground, replace the OPC unit. • If there is no charge PWM signal, replace the harness and/or VBCU.