Code: SC746
Description: Stack Plate Motor Error 1: Front Motor (B830)
The stack plate HP sensor (front) does not activate within 500 ms after the motor turns on. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
The stack plate HP sensor (front) does not activate within 500 ms after the motor turns on. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
Causes: If the motor is operating 1. Front stack plate HP sensor harness loose, broken, defective 2. Front stack plate HP sensor defective If the motor is not operating: 1. Motor blocked by an obstruction 2. Motor harness loose, broken, defective 3. Motor defective 4. Booklet finisher main board defective