Mã lỗi SC220-03 — Ricoh Aficio MPC6502SP

Code: SC220-03

Description: Leading Edge: LD1 synchronization detection error: Ma. The leading edge LD1 synchronization detection signal of the corresponding color was not output within 100 ms while the polygon mirror motor was operating at normal speed. Details: • When a synchronization detection error flag is asserted to VTEC status register. • After the polygon turned on, the CPU monitored for error flags in 100 ms cycles and detected an error flag.
Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly. • Synchronization detection board defective • Beam does not enter photodetector.. • Abnormality around VTEC • LDB defective • BCU defective • Large main scan magnification rate
Remedy: • Cycle the machine off/on. • Replace the LSU board. • Replace the IPU board. • Replace the BCU board. • Correct the main scan magnification SP* * SP2-184-006 through 009 = 269600 SP2-102-001,007 = 123 SP2-102-016 through 025 = 0 • Adjust SP2-184-006 through 009 while checking the images until the values of SP2-102-001,007 become 123 ± 30.