Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC509-02 — Ricoh Aficio MPC6502SP

Code: SC509-02

Description: Bypass tray lowering error The bottom plate started CCW but the tray upper limit sensor did not become non-blocked within 1.5 seconds. If detected for the first or second time: User is instructed to set paper again. If detected for the third time: SC displayed The count of detections is reset when successful operation is detected and at power off/on.
Causes: • Bypass tray upper limit sensor defective/disconnected/harness broken • Bypass tray bottom plate lift motor defective/disconnected/harness broken • Circuit board (PFB) error • Bypass tray bottom plate/bottom plate drive unit does not move e.g. because physical obstacle (broken piece of the unit, etc.) is blocking operation.
Remedy: • Bypass tray bottom plate lift motor and bypass tray bottom plate upper limit sensor check/cleaning/replacement/harness reconnection/harness replacement • Check or replace the circuit board (PFB). • Check and/or replace the bypass tray bottom plate and bottom plate lift drive unit.