Code: 792-14
Description: 50/100 clamp adjustment error
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
Causes: • 50/100 adjustment motor (M702) connector loose, broken, defective • Motor overload • Motor defective • Ring switch HP sensor (S706) connector loose, broken, defective, or sensor defective • Ring switch timing sensor (S707) connector loose, broken, defective, or sensor defective