Mã lỗi 795-3 — Ricoh Aficio Pro C900S

Code: 795-3

Description: Slave-to-Cutter Control Board Communication Error PB (D391) Slave-to-Cutter Board Communication Error 1 Slave control board could not communicate with the cutter control board (it detected the communication alarm for over 5 sec.
Causes: • Cutter board connector loose, broken, defective • Cutter control board defective Slave-to-Cutter Board Communication Error 2 Cutter control board could not communicate with the slave control board and detected the communication alarm for over 5 sec. More than twice the maximum allowed alarm recovery time (2 to 3 sec.) • Slave control board connectors loose, broken, defective • Cutter control board connectors loose, broken, defective • Slave control board defective • Cutter control board defective Download Error The version of the firmware on the cutter control board could not be detected at power on. Communication between the slave and cutter control boards is not possible if the cutter board firmware cannot be written to the board. • Cutter control board connection loose, broken, defective • Cutter control board defective
Remedy: