Code: 541
Description: Fuser thermistor error
The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
Causes: • Disconnected or defective thermistor • Disconnected or defective fusing lamp 1. Check the harness connection of the thermistor. 2. Replace the fusing unit. • Execute "Reset Fusing Unit SC" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.