Code: 542
Description: Fuser reload error
This SC is issued if one of following conditions occurs: The fusing temperature rises 8°C or less in 1.5 seconds; and this continues 5 times consecutively. -or- The fusing temperature has not reached 45°C within 9 seconds (after the fusing lamp comes ON while the machine is warming-up). -or- The fusing unit does not attain reload temperature within 35 s. (normal temperature) or 65 s (lower temperature – the thermistor output is less than 18°C) after the fusing temperature control starts.
This SC is issued if one of following conditions occurs: The fusing temperature rises 8°C or less in 1.5 seconds; and this continues 5 times consecutively. -or- The fusing temperature has not reached 45°C within 9 seconds (after the fusing lamp comes ON while the machine is warming-up). -or- The fusing unit does not attain reload temperature within 35 s. (normal temperature) or 65 s (lower temperature – the thermistor output is less than 18°C) after the fusing temperature control starts.
Causes: • Defective or deformed thermistor • Incorrect power supply input at the main power socket 1. Defective fusing lamp