Code: 350
Description: ID sensor pattern test error
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1. Vsp greater/equal 2.5V 2. Vsg less than/equal 2.5V 3. Vsp = 0V 4. Vsg = 0V
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1. Vsp greater/equal 2.5V 2. Vsg less than/equal 2.5V 3. Vsp = 0V 4. Vsg = 0V
Causes: • ID sensor defective • ID sensor harness or connector loose, broken, defective • IOB defective • HVPS board defective • ID sensor dirty