Code: 541
Description: Fusing thermistor open
After the hot roller center thermistor temperature reached 45C (113F), the center fusing temperature failed to reach 60C (140oF) within 2 sec. for 5 counts at 0.1 sec. intervals. -or- After the hot roller end temperature thermistor reached 45oC (113F), the end fusing temperature failed to reach 57C (135F) within 2 sec. for 5 counts at 0.1 sec. intervals.
After the hot roller center thermistor temperature reached 45C (113F), the center fusing temperature failed to reach 60C (140oF) within 2 sec. for 5 counts at 0.1 sec. intervals. -or- After the hot roller end temperature thermistor reached 45oC (113F), the end fusing temperature failed to reach 57C (135F) within 2 sec. for 5 counts at 0.1 sec. intervals.
Causes: • Fusing thermistor disconnected • Fusing thermistor connector defective • Fusing thermistor damaged, warped, or out of position • Input voltage less than 15% of the standard input voltage