Code: 543
Description: Fusing overheat error (software detection)
A fusing temperature of over 230C (446F) is detected for 5 seconds by the fusing thermistors at the center or at either end of the hot roller.
A fusing temperature of over 230C (446F) is detected for 5 seconds by the fusing thermistors at the center or at either end of the hot roller.
Causes: • Check harnesses and connectors of PSU, IOB, BICU • PSU defective • IOB defective • BICU defective • Fusing thermistor defective or wrong type