Code: 543
Description: High Temperature Detection Error
This SC is issued if one of following conditions occurs: The thermistor (center) detects 255°C or thermistor (end) detects 245°C. The thermistor (center) detects a 3°C increment or more for five seconds at 220°C or more or the thermistor (end) detects a 4°C increment or more for five seconds at 210°C or more.
This SC is issued if one of following conditions occurs: The thermistor (center) detects 255°C or thermistor (end) detects 245°C. The thermistor (center) detects a 3°C increment or more for five seconds at 220°C or more or the thermistor (end) detects a 4°C increment or more for five seconds at 210°C or more.
Causes: Defective I/O control (EGB). Defective EGB.
Remedy: 1. Replace the EGB • Execute "Fuser SC Reset" with SOM to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.