Code: 205
Description: Polygon motor error: XSCRDY signal not stable
PMRDY_N signal consecutively detects that the polygon motor is an inactive state while the polygon motor turns on or changes the speed.
PMRDY_N signal consecutively detects that the polygon motor is an inactive state while the polygon motor turns on or changes the speed.
Causes: Disconnected cable from the polygon motor drive board or defective connection. Defective polygon motor or drive board.
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.