Code: 547
Description: Zero cross error
The zero cross signal is detected three times even though the heater relay is off when turning on the main power. The zero cross signal is not detected for three seconds even though the heater relay is on after turning on the main power or closing the front door. The detection error occurs twice or more in the ten zero cross signal detections. This error is defined when the detected zero cross signal is less than 17 for 200 ms.
The zero cross signal is detected three times even though the heater relay is off when turning on the main power. The zero cross signal is not detected for three seconds even though the heater relay is on after turning on the main power or closing the front door. The detection error occurs twice or more in the ten zero cross signal detections. This error is defined when the detected zero cross signal is less than 17 for 200 ms.
Causes: Defective fusing lamp relay. Defective fusing lamp relay circuit. Unstable power supply.
Remedy: 1. Check the power supply source. 2. Replace the PSU.