Code: 559
Description: Continuous paper jam at Fusing unit
The paper jam occurs three times consecutively at the fusing unit only when the SP 1159 1 is set to "1 (ON)". If not, this SP does not occur. The jam counter is cleared when a sheet of paper is fed normally.
The paper jam occurs three times consecutively at the fusing unit only when the SP 1159 1 is set to "1 (ON)". If not, this SP does not occur. The jam counter is cleared when a sheet of paper is fed normally.
Causes: Defective fusing entrance sensor. Defective EGB.
Remedy: 1. Replace the fusing entrance sensor. 2. Replace the EGB.