Code: 652
Description: Remote service ID2 mismatch error
The ID2 in the individual certificate does not match the ID2 in the NVRAM on the controller board.
The ID2 in the individual certificate does not match the ID2 in the NVRAM on the controller board.
Causes: • The controller board in this machine has already been used in a machine in which RC Gate was installed. • The controller board NVRAM in this machine has already been used in a machine in which RC Gate was installed.
Remedy: If an error occurs at installation of the RC Gate: 1. Check that the individual certificate is correct for the NVRAM in the machine and that the ID2 is correct. 2. Reinstall the RC Gate after writing the common certificate. If an error occurs after installation of the RC Gate: 1. Clear the RC Gate data. 2. Check that the individual certificate is correct for the NVRAM in the machine and that the ID2 is correct. 3. Reinstall the RC Gate after writing the common certificate.