Code: 622
Description: 2nd paper bank (option) communication error • While the bridge board communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The bridge board receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the bridge board does not receive an OK signal from a peripheral 100ms after sending a command to it. The bridge board resends the command. The bridge board does not receive an OK signal after sending the command 3 times.
Causes: • Cable problems • Bridge board problems • BCU problems • PSU problems in the machine • Main board problems in the peripherals
Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the bridge board or main board of peripherals. 3. Replace the BCU if no power is supplied to peripherals.