Code: 370-02
Description: TM(ID) Sensor calibration error (Left)
The specular light output voltage (Vsg_reg) of the Left TM(ID) Sensor cannot be calibrated to a value in the target range. Upper limit (initially 2.97 V) Lower limit (initially 2.31V)
The specular light output voltage (Vsg_reg) of the Left TM(ID) Sensor cannot be calibrated to a value in the target range. Upper limit (initially 2.97 V) Lower limit (initially 2.31V)
Causes: - Disconnected TM(ID) Sensor connector/bad contact - Stained TM(ID) Sensor window - Failed TM(ID) Sensor - Image Transfer Belt loosened or out of place
Remedy: • Check the TM(ID) Sensor • Clean the TM(ID) Sensor Detection window • Check the Image Transfer Belt • Replace the TM(ID) Sensor